Flow Meter Oval Delta Flowpet DX can be used for measure steam and gas max. operating temperature of 200℃.
Pressure correct on function furnished high accuracy, low cost vortex flowmeter
- Built-in pressure sensor (for steam and gas)
- Max. operating temperature of 200℃
- Low pressure loss
- High accuracy and low cost type
Specification :
Nominal Size | 15, 25, 40, 50, 80, 100, 150 |
Connection | Wafer type |
Connection standard | JIS 10, 16, 20, 30K/ASME or JPI 150, 300 |
Wetted parts material | SCS14A or SUS316, other |
Flow Range | 12.4 to 8820kg/h (0.5 MPa saturated steam) |
Accuracy | ±2.0% RD (at 0.25 MPa or more) |
Operating temp. range | -30 to +200℃ |
Max. operating pressure | 1.0MPa (with 5.0 MPa liquid) |