Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the kirki domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/ptsriayumultikreasi.com/httpdocs/wp-includes/functions.php on line 6114
Pressure Gauge Models 111.10 - PT. SRIAYU MULTI KREASI

Pressure Gauge Models 111.10


Description

The model 111 pressure gauges are based on the proven Bourdon tube measuring system. On pressurisation, the deflection of the Bourdon tube, proportional to the incident pressure, is transmitted to the movement via a link and indicated.

The modular design enables a multitude of combinations of case materials, process connections, nominal sizes and scale ranges. Due to this high variance, the instrument is suitable for use in a wide range of applications within industry.

For mounting in control panels, the pressure gauges can, depending on the process connection, be fitted with a surface mounting flange or with a triangular and mounting bracket.

The standard version of the model 111 is manufactured, cost-optimised on modern production lines, in volumes of several million instruments per year.

Applications

  • For gaseous and liquid media that are not highly viscous or crystallising and will not attack copper alloy parts
  • Pneumatics
  • Heating and air-conditioning technology
  • Medical engineering

Special Features :

  • Reliable and cost-effective
  • Design per EN 837-1
  • Nominal size 40, 50, 63, 80, 100, and 160
  • Scale ranges up to 0…..400 bar

 

Specification :

Design

EN 837-1

Nominal Size in mm

40, 50. 63, 80, 100

160 only with model 111.10

Accuracy class

2.5

Scale Ranges

0…..0.6 to 0…..400 bar (NS 160 : max. 40 bar) or all other equivalent vacuum or combined pressure and acuum ranges.

Pressure limitation

Steady : 3/4 x full scale value

Fluctuating : 2/3 x full scale value

Short time : Full scale value

Permissible temperature

Ambient : -20…+60°C

Medium : +60°C maximum

Temperature effect

When the temperatureof the measuring system deviates from the reference temperature (+20°C) : max. ±0.4 %/10 K on the span.

Process Connection

copper alloy

C-type or helical type

Movement

Copper alloy

Dial

NS 40, 50, 63 : Plastic, white, with pointer stop pin

NS 80, 100, 160 : Aluminium, white, with pointer stop pin

Black lettering, red mark pointer with measuring ranges

0….0.6 to 0….60 bar

Pointer

Plastic, black

NS 160 : Aluminium, black

 