Pressure Gauge WIKA Model PG23CP


DESCRIPTION

The high-quality model PG23CP pressure gauge has been designed especially for the requirements of the process industry. This safety pressure gauge is mainly used for applications in the chemical and petrochemical indusrty, the oil and gas industry, power engineering and also in water/wastewater technology.

Typical measuring points are on control units and control panels such as hydraulic power units (HPUs). For secure mounting of the instrument, a high-quality front bezel is used. The mounting situations mainly require an IP66 ingress protection. For this reason, the sealing of the model PG23CP to the panel is made using an all welded mounting ring and a mattched flat gasket.

Pressure gauges for the process industry are manufactured completely from stainless steel for increased corrosion resistance. This enables use in the measurement of aggressive gaseous or liquid media, also in aggressive environments. In the EN 837-1 standard for pressure gauges, safety versions are defined. For most applications, a safety version is not required.

APPLICATIONS

  • For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments
  • Specifically for the requirements within the process industry, mainly in the chemical and petrochemical industry, the oil and gas industry, power engineering and also in water/wastewater technology
  • Particulary suitable for use in welhead control panels (WHCPs) and hydraulic power units.

SPECIAL FEATURES

  • All welded mounting ring to avoid ingress of water into the panel (ingress protection IP6)
  • All stainless steel construction
  • Optionally as safety version “S3” per EN 837-1

STANDARD VERSION

Version

EN 837-1

Nominal size in mm

63, 100

Accuracy class

NS 63: 1.6

NS 100: 1.0

Scale ranges

NS 63: 0 … 1 to 0 … 1,000 bar

NS 100: 0 … 0.6 to 0 … 1,600 bar

or all other equivalent vacuum or combined pressure and vacuum ranges

Pressure limitation

NS 63:

Steady: 3/4 x full scale value

Fluctuating: 2/3 x full scale value

Short time: Full scale value

NS 100:

Steady: Full scale value

Fluctuating: 0.9 x full scale value

Short time: 1.3 x full scale value

Permissible temperature

Ambient: -40 … +60 °C

Medium: +200 °C maximum

Temperature effect

When the temperature of the measuring system deviates from the reference

temperature (+20 °C): max. ±0.4 %/10 K of full scale value