Control Valve SOCLA CL701 has Application and general characteristics :
- It prevents from overflowing from overflowing and maintains a constant level in the tank thank to a float
- Opening and closing are very progressive, (a few centimeters from the required level)
- Prefer the installation at the bottom of the tank or close to it
Working Principle
The level in the tank is low and the float switch S is fully open. The valve A is wide open and supplies the tank
The float is in intermediary position, the float switch is half closed. Consequently, the head loss increases the pressure in the upper chamber, the valve A will close. It will be completely closed as soon as no flow runs out from the float switch in high position
Installation Example and spare part List
N° | Description | Material |
A | Main Valve | Cast iron |
B | Upstream isolation valve | Nickel plated brass |
C | Drain clock | Brass |
D | Chamber isolation valve | Nickel plated brass |
E1 | Downstream isolation valve | Nickel Plated brass |
G | Strainer | Brass |
H | Orifice | Stainless steel |
S | Pilote | Bronze-Stainless steel-copper float |
N° | Description |
1 | Isolation valve of the by-pass |
2a-2b | Isolation valves of the main water pipe |
3 | Rubber expansion joints |
4 | Non-return valve |