Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the kirki domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/ptsriayumultikreasi.com/httpdocs/wp-includes/functions.php on line 6114
High Accuracy & high resolution ( PC Link ) SANWA PC720M - PT. SRIAYU MULTI KREASI

High Accuracy & high resolution ( PC Link ) SANWA PC720M


87,328 points data logging in built-in memory

  • 4 digits 9999 count & 3-5/6 digits 6000 count
  • AC True RMS
  • Dual display with backlight
  • Automatic measurement for ACV/DCV/Ω under low impedance
  • High speed bar graph
  • Capacitance measurement
    * Not suitable foe measurement of condesers with large leak current.
  • K Type temperature -500C – 1000C
    * Optional accessory K-AD is necessary
    * K Type temp. sensor K-250PC is included as a standard accessory.
  • Frequency measurement ( AC sine wave only )
  • Logic frequency measurement, duty cycle measurement
  • Conductance measurement
  • MAX, MIN, MAX-MIN recording mode.
  • Capture ( peak hold ) 1 ms in duration.
  • Data hold, Range hold.
  • Relative value.
  • Auto power saving mode ( 30 min ) ( cancelable )
  • Optical Link USB interface ( optional ).

Data logging Mode

  • 87,328 data points in built-in memory ( single display )
    43.664 data points in built in memory ( dual display )
  • Selection of measurement interval
    0.05s/0. 1s/0. 5s/1s/2s/3s/4s/5s/10s/15s/30s/60s/120s/180s/300s/600s
  • Auto-standby mode when a sampling speed of 30s or longer is selected
  • Export logged data PC
    * Optional accessory KB-USB7 and PC Link7 are necessary.

Display : Numeral display 9999 & 6000, bar graph

Safety : IEC61010-1, IEC61010-31 CAT.III 600 Max. / CAT. II 1000V Max. EN61326-1

Battery life : Approx. 100h ( Alkaline battery ) at DCV range

Optional Accessories

Software : PC Link7

Optical PC link cable : KB-USB7

Clamp probe : CL-22AD, CL33DC, CL3000

Temperature probe : T-300PC ( PC Link software is necessary ) K-8-250-800

K Type adapter : K-AD

Test lead : TL-21M, TLF-120

Carrying case : C-PC7

Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC