Flow Meter Avery Hardoll BM 450


Flow Meter Avery Hardoll BM 450 flowmeters are precision made, positive displacement, liquid measuring instruments that maintain the highest level of accuracy over a lifetime of operation. Simplicity of design and accuracy has resulted in the Avery Hardoll BM Series meters to being the most preferred meters by aviation fueling operators and airlines in international markets.

BM Series bulkmeters are manufactured in three basic sizes with different ratings identified by a series number.

The series numbers, sizes, flow rates, and a brief description of each series of meter are shown below.

TYPES OF BULKMETER

  • Serial Number : BM450
  • Manifolds : 3 inches, 76 millimeters
  • Flow Rates : 45– 450 Imperial Gallons, 200 – 2050 liters
  • General Description : Double Capsule Meters

BULKMETER MAIN COMPONENTS

  • The BM Series bulkmeters consist of three main assemblies: the manifold, body assembly and rotor assembly
  • The higher rating of the larger meters is achieved by bolting two or three body capsules together and fitting double or triple rotor assemblies with a larger manifold to suit
  • A calibrating mechanism and mechanical register are also attached to the front end cover
  • The calibrating mechanism can be replaced by a front cover incorporating a pulse transmitter when required for electronic systems, such as MASTERLOAD II™ or MASTERLOAD III™ registers

Specification Of Flow Meter Avery Hardoll BM 450 Series :

Meter Series : BM450

Pipeline Size : 2-2½” (63mm)

Flow Rate : 25 to 250 Imp. Gal, 115 to 1140 lpm, 7 to 68 M³/h

Flanges Conform To : ASA 150 FF

Flanges Material : Ductile Iron Stee

 

VISCOUS PRODUCTS :

Avery Hardoll bulkmeters can be used on all petroleum products of all viscosities. However, there is an increase in pressure drop with more viscous fuels, which under normal circumstances will limit the maximum flow rate obtainable. It is recommended that the pressure drop through a bulkmeter should not exceed 15 psi (1 bar), above which the load on the bearings will start to cause wear.

Consequently when using products with viscosities above 100 centistokes (at operating conditions), it is necessary to reduce the maximum permitted flow rate. As a guide, it is suggested that the pressure drop through the meter should not exceed 10 psi (0.7 bar) for continuous running at maximum speed or 15 psi (1 bar) for continuous running at half speed. The low pressure drop for the BM Series of Avery Hardoll bulkmeters is displayed on the left.

 

Flow Meter Avery Hardoll BM 450 Series