Itron Woltex 4 Inch


Itron Woltex 4 Inch is a horizontal helix Woltman meter suitable for cold water and clean water, can be used for industrial needs. Available size for 2 inch 50mm, 3 inch 80mm, 6 inch 150mm, 8 inch 200mm, 10 inch 250mm.

FEATURES :

  • Extended Approved Range
    Woltex is approved with normal flow range as per ISO 4064-1:1993, as class B and also, with superior permanent flow-rate. It means that one size (DN) has 2 different flow range :
    • N for Normal Permanent Flow Rate;
    • G for Greater Permanent Flow Rate;
  • Ease of Installation, Read and Maintenance
    Woltex range is available in various lengths and connections to minimize installation costs. Interchangeable approved mechanisms allows easy maintenance without re-calibration. Ease of read in the toughest environments (ie: flooded pits) is secured by orientable hermetically sealed register (copper can/ mineral glass envelope).
  • Endurance & Peak Flow Resistance
    This extended approval is the result of more than twenty years experience in Horizontal Woltmann design, from the first hydrodynamically balanced helix patent in 1985 still resulting in unmatched endurance capabilities to the use of high quality materials.

COMMUNICATION :

Woltex is supplied pre-equipped with Cyble Target Allows communication and remote reading through:

  • Pulse output (Cyble Sensor)
  • M-Bus protocol (Cyble M-Bus)
  • Radio frequency wireless link (Cyble RF)
    Compatible with Itron complete offer for Metering Point Management (Automated Remote Reading, Metering Point Analyser, Automated Meter Data Collection):
  • AnyQuest
  • EverBlu
  • WaterMind
    These Cyble modules allow the Woltex meter to be connected with various associated systems if and when desired. They are particularly adapted to commercial and industrial applications where a need for frequent meter monitoring is expressed especially in hard-to-read locations.

Metrological Characteristics Itron Woltex 4 Inch

  • Nominal diameter (DN) : 100 mm 4 inch
  • Starting flowrate : 0.38 m3/h
  • Accuracy ± 2% from : 1.5 m3/h
  • Accuracy ± 5% from : 0.9 m3/h
  • Admissible peak flow (10’ max) : 300 m3/h
  • Max. admissible flowrate (continuous) : 200 m3/h
  • Head loss at Qmax ; 0.23 bar
  • Max. admissible temperature ; 50°C
  • Max. admissible pressure : 20 bar
  • Min. scale interval (L) : 20
  • Indicating range : 9999999.9 m3
  • Cyble HF pulse weight (L) : 100
Itron Woltex 4 Inch

Have any Question or Comment?

Leave a Reply

Your email address will not be published. Required fields are marked *

Categories

LOKASI

Copy Protected by Chetan's WP-Copyprotect.