LUTRON AM-4205A HUMIDITY-ANEMOMETER


Detail LUTRON AM-4205A HUMIDITY-ANEMOMETER :

  • Anemometer, Humidity/Temp. and Type K/J thermometer metearw combined into one meter, intelligent design
  • Microprocessor circuit ensure high accuracy and also provides special functions and features
  • Super large LCD display eith contrast adjustment for best viewing angle
  • Dual function meter’s display
  • Low-friction ball vane wheels is accurate in both high and low velocities
  • Thin-film capacitance sensor for humidity measurement high precision, fast response
  • Records maximum and minimum readings with recall
  • Data hold
  • Auto power off saves battery
  • RS232 PC serial interface
  • The portable anemometer provides fast, accurate readings, with digital readibility and the convenience of a remote sensor separately
  • Multi-funtions for air flow measurement : m/s, km/h, ft/min, knots.mile/h
  • Build in temperature measurement . ℃ ℉
  • Thermistor sensor for temp. measurement , fast response time.
  • Used the durable, long-lasting components
  • Heavy duty and compact housing case
  • Deluxe hard carrying case, easy carryout and storage
  • Wide applications : To check air conditioning and heating systems, measure air velocities, wind speeds, humidity temperature… etc

GENERAL SPECIFICATIONS :

  • Circuit : Custom one-chip microprocessor LSI circuit
  • Display : Dual function meter’s display, 13 mm ( 0.5 inch ) super large LCD display
  • Measurement :
    Anemometer : m/s, km/h, ft/min, knots. mile/h, Temp. ℃ ℉,
    Humidity meter : R.H. ( Relative Humidity ), Temperature- ℃ ℉,
    Type K Thermometer : -199℃ to 1300.0 ℃ ; -327.8℉ to 2372.0℉
  • Sensor structure :
    1. Anemometer
    * Air velocity : Conventional twisted van arm and low friction ball bearing design
    * Temperature : Precision thermistor
    2. Humidity Meter
    * Humidity : High precision thin-film capacitance sensor
    * Temperature : Precision thermistor
    3. Type K/J Thermometer : Thermocouple probe
  • Data hold : To freeze the display reading on the LCD display
  • Sampling time : Approx. 0.8 second
  • Memory recall : Records maximum and minimum readings with recall
  • Power off : Auto shut off saves battery life or manual off by push button
  • Data output : RS232 PC serial interface
  • Operating temperature : 0C to 50C ( 32F to 122F ).
  • Operating humidity : Less than 80% RH
  • Power supply : 006P DC 9V battery ( heavy duty type )
  • Power consuption : Approx DC 8.3 mA
  • Weight : 350g/ 0.77 LB, main instrument
  • Dimension :
    Main instrument : 180x72x32 mm
    Anemometer probe : Round, 72 mm Dia
    Humidity probe : Round 26 mm Dia x 160 mm