LUTRON TM-966A Forehead IR Thermometer


Detail LUTRON TM-966A Forehead IR Thermometer :

  • Non-contact temperature measurement, -30◦C to 300◦C (-22◦F to 572◦F)  precision for forehead no contact temperature measurement
  • 0.1 degree resolution, high precision, exclusive design for the human forehead temperature measurement
  • Useful instrument to find the not normal ( extra higher ) human body temperature in the crowd quickly
  • Automatic data hold
  • Back light LCD display
  • High repeatability with 0.3 ◦C
  • ◦C, ◦F, display unit, select by internal switch
  • IR measurement with red LED light guide, safety.
  • Microprocessor circuit
  • Gun type, heavy duty & compact housing case.
  • Data hold function to freeze the display reading
  • LCD display, asy readout
  • Operates from 006P DC 9V battery.

GENERAL SPECIFICATIONS :

  • Circuit : Custom one-chip of micro processor LSI circuit
  • Display : LCD, 29 X 33 mm
  • Functions : ◦C & ◦sF, Auto data hold, Auto power off, Auto LCD backlight
  • Sampling time : Approx 0.6 second
  • Hold and auto power off function : After release the operation switch, display will hold the last measuring value within 5 seconds continiously.
  • Power supply : DC 9V battery, 006P, or equivalent, heavy duty or alkaline.
  • Power consumption :
    With LED target light ON : Approx DC 48 mA
    Without LED target light ON : Approx DC 12 mA
  • Operating temperature : 0◦C to 50◦C ( 32◦F to 122◦F ).
  • Measuring range :
    Forehead temperature measurement : 32◦C to 42.0◦C (89.6◦F to 107.6◦F)
    Room temp. measurement : 0◦C to 100.0◦C (32.0◦F to 212◦F)
  • Resolution : 0.1◦C (0.1 ◦F)
  • Accuracy :
    Forehead temperature measurement :
    ± 0.5 ℃
    * Under measuring range : 35.0 to 42.0 ℃
    * Within 23 ± 5 ℃ ambient operating
    * Spec. testing under distance is 3 cm
  • Repeatability :
    ± 0.5 ℃
    * Under measuring range : 35.0 to 42.0 ℃
    * Within 23 ± 5 ℃ ambient operating
    * Two measuring data that test between 1 minute

    * Spec. testing under distance is 3 cm
  • Measuring distance : 2 to 5 cm
  • IR sensor : Thermocouple pie
  • Light : Red LED light safety for human eye
  • Emissivity setting : 0.95
  • Measuring wave length : 6 to 12 micro meter
  • Distance factor : D/S : Approx 7;1 ( D= Distance, S=Spot )

 

 

 

 

 