LUTRON YK-2005AH Hot Wire Anemometer


Detail LUTRON YK-2005AH Hot Wire Anemometer :

  • Combination of hot wire and standard thermistor, deliver rapid and precise measurements even at low air velocity value.
  • Slim probe, ideal for grilles and diffusers
  • Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,
  • Air flow : CMM ( m^3/min.) and CFM ( ft^3/min. )
  • Air temperature (°C, °F)
  • Type K/J thermocouple thermometer
  • Real time data logger, build in clock ( hour-minute-second-year-month-date )
  • Auto data record 16.000 Data logger no
  • Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds
  • Zero adjustment
  • Can default auto power off or manual power off
  • Can default the air velocity, air flow, Temp.unit
  • Air flow measurement can set the are dimension
  • Large LCD with multiple display
  • Data hold, record max. and min reading
  • Microcomputer circuit provides special function and offer high accuracy
  • Air temp. user thermistor sensor, fast response time
  • Power by UM3 ( 1.5V ) x 4 batteries or DC 9V adapter
  • RS232 PC serial interface
  • Separate probe, easy for remote measurement
  • Applications : Environmental testing, air convenyors, Flow hoodsm clean rooms, Air velocity, Air balancing, Fans/motors/blowers. Furnace velocity, Refrigerated case, Paint spray booths.

GENERAL SPECIFICATIONS :

  • Circuit : Custom one-chip microprocessor LSI circuit
  • Display : LCD size : 58X34mm
  • Measurement unit :
    Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,
    Air flow : CMM ( m^3/min.) and CFM ( ft^3/min.),
    Air temperature (°C, °F)
    Type K/J thermometer : (°C, °F)
  • Sampling time of data logger : 2 sec 8 hour 59 min. 59 sec. @Auto datalogger
  • Sensor structure :
    Air velocity and air flow : Tiny glass bead thermistor
    Air temperature : Thermistor
    Type K/J thermometer : Thermocouple
  • Temperature compensation : Automatic temp.
    compensation fot the type K/J thermometer
  • Data hold : Freeze the display reading
  • Memory recall : Maximum and minimum value
  • Sampling time of display : Approx 1 second
  • Power off : Auto shut off saves battery life or manual off by push button
  • Data output : RS232 PC serial interface
  • Operating temperature : 0C to 50C
  • Operating humidity : max. 80% RH
  • Power supply ( Clock module ) : DC 3V silver battery Type : CR2032
  • Power current :
    Approx DC 21.5 mA ( Main instrument )
    Approx DC 70 mA ( Main instrument + Hot wire probe )
  • Weight : 515 g / 1.13 LB ( Battery included )
  • Dimension :
    Main instrument : 203x76x38 mm
    Telescope : * Round, 12 mm Dia x 280 mm ( Min length ) * Round 12 mm Dia x 940 mm ( max.length )