Specification product:
Single Phase ( PQAm 80 ),Three Phase ( PQA 80 )
Power:
KW: 0.75
HP: 1
Flow Rate (Q) = m3/h : Total manometric head = metres
0: 70
0.1: 66
0.3: 62
0.6: 56
0.9: 49.5
1.2: 43
1.5: 37
1.8: 31
1.9: 28
2.3: 20.5
2.7: 12
Flow Rate (Q) = l/min : Total manometric head = metres
0: 70
2: 66
5: 62
10: 56
15: 49.5
20: 43
25: 37
30: 31
32: 28
38: 20.5
45: 12
Ports
Inlet: 1/2″
Outlet: 1/2″
Berat: Single Phase : 9.4 kg
Three Phase : 8.4
PERFORMANCE RANGE
- Flow rate up to 45 l/min (2.7 m³/ h)
- Head up to 65 m
APPLICATION LIMITS
- Manometric suction lift up to 8 m
- Liquid temperature between -10 ° C and +90 °C
- Ambient temperature between -10 °C and +40 °C
- Max. working pressure 10 bar
- Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
EN 60335-1 EN 60334-1
IEC 60335-1 IEC 60334-1
CEI 61-150 CEI 2-3
CERTIFICATIONS
Company with management system certified DNV ISO 9001 : QUALITY
ISO 14001: ENVIRONMENT
INSTALLATION AND USE
The PQA pumps are recommed for pumping clean water without abrasive particles and with liquids which are not chemically aggressive towards the materials with which the pump is made.
The RYTON and brass pump body construction guarantees againts the formation of rust and oxidation. Because of these characteristics these pumps are suitable for use in industrial applications such as cooling, air conditioning, laundries, etc. The pump should be installed in an enclosed environment or sheltered from inclement weather.
PATENTS – TRADE MARKS – MODELS
- Motor bracket: patented n. IT1243605
- Shaft: patent n. 0000275945 (PQA60)
OPTIONS AVAILABLE ON REQUEST
- Special mechanical seal
- EN 10088-3 – 1.4401 (AISI 316) stainless steel motor shaft
- Other voltages or 60 Hz frequency
- IP X5 Class protection for PQA70