Design

EN 837-3

Nominal size in mm
63, 100, 160
Accuracy class
1.6

Scale ranges

NS 63: 0 … 40 mbar to 0 … 600 mbar

NS 100: 0 … 16 mbar to 0 … 600 mbar

NS 160: 0 … 2.5 mbar to 0 … 600 mbar
or all other equivalent vacuum or combined pressure and vacuum ranges or all other equivalent vacuum or

combined pressure and vacuum ranges

Pressure limitation

Steady: Full scale value

Fluctuating: 0.9 x full scale value

Permissible temperature

Ambient: -20 … +60 °C

Medium: +100 °C maximum
Temperature effect

When the temperature of the measuring system deviates from the reference temperature (+20 °C):

max. ±0.6 %/10 K of full scale value.

APPLICATION

  • With liquid-filled case for applications with high dynamic pressure loads or vibrations
  • For gaseous, dry and aggressive media, also in aggressive ambience
  • Process industry : Chemical/petrochemical, pharmaceutical, biotechnology, machine and power generation industries.

SPECIAL FEATURES

  • Zero adjustment at the front
  • All stainless steel construction
  • Special connection location on request
  • Low scale ranges from 0…..2.5 mbar