APPLICATION
- Pressure measurement at very low pressure
- For gaseous, aggressive media, also in aggressive environments
- Robust design and ingress protection IP54, suitable for outdoor use
SPECIAL FEATURES
- High overload safety up to 50 x full scale value
- Measuring chamber protected against unauthorised intervention
- Low measuring error and influence from medium pollution
DESCRIPTION PRODUCT
Nominal size in mm
100, 160
Accuracy class
1.6
Scale ranges
0 … 2.5 to 0 … 100 mbar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Overload safety
50 x full scale value
Permissible temperature
Ambient: -20 … +60 °C
Medium: +100 °C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference
temperature (+20 °C): max. ±0.6 %/10 K of full scale value