Specification product:
Single Phase ( RXm 3 )
Power:
KW: 0.55
HP: 0.75
Flow Rate (Q) = m3/h : Total manometric head = metres
0: 12
1.2: 11.5
3.6: 9.5
6.0: 8
8.4: 6.5
9.6: 5.5
12.0: 3.5
13.2: 3
Flow Rate (Q) = l/min : Total manometric head = metres
0: 12
20: 11.5
60: 9.5
100: 8
140: 6.5
160: 5.5
200: 3.5
220: 3
Ports
Outlet: 1 1/4″
Berat: 7.4 kg
PERFORMANCE RANGE
- Flow rate up to300 l/min (18 m³/ h)
- Head up to 20 m
APPLICATION LIMITS
- 10 m maximum immersion depth
( with a sufficiently long power cable )
- Maximum liquid temperature +50 °C
( Maximum liquid temperature +90 °C)
for a maximum of 3 minutes intermittent service )
- Passage of suspended solids up to Ø 10 mm
- Suction level:
– 14 mm above ground level for RX 1-2-3
– 25 mm above ground level for RX 4-5
- Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
The pumps are complete with;
– 5 m long power cable for RX 1-2-3
– 10 m long power cable for RX 4-5
–Float switch for single-phase versions
EN 60335-1 EN 60334-1
IEC 60335-1 IEC 60334-1
CEI 61-150 CEI 2-3
CERTIFICATIONS
Company with management system certified DNV ISO 9001 : QUALITY
ISO 14001 : ENVIRONMENT
INSTALLATION AND USE
The RX series pumps are suitable for use with clear water that does not contain abrasive particles.
Because of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable.
They are suitable for use in fixed installations and applications such as draining small floodd areas ( rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home ( from dishwashers, washing machines) and for emptying drainage traps.
PATENTS-TRADE-MARKS-MODELS
- Patent n. IT0001390742 ( RX 4-5)
- Registered EU Design n. 342159 – 0 013 ( R X 1-2-3 )
OPTIONS AVAILABLE ON REQUEST
- “RX – GM”pumps with a vertical float switch ( suitable for particularly small wells)
- Special mechanical seal
- RX 1-2-3 pumps with a 10 m long power cable.
=> N.B: Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor
applications
- Single-phase pumps without float switch.
- other voltages or 6o Hz frequency