Specification product:
Three Phase ( 2CP 40/180A )
Power:
KW: 7.5
HP: 10
Flow Rate (Q) = m3/h : Total manometric head = metres
0: 88
6.0: 85
6.6: 84.5
7.5: 84
8.4: 83
9.6: 82
10.8: 81
12.0: 79.5
15: 76
18.0: 72
21.0: 67
24.0: 60
Flow Rate (Q) = l/min : Total manometric head = metres
0: 88
100: 85
110: 84.5
125; 84
140: 83
160: 82
180: 81
200: 79.5
250: 76
300: 72
350: 67
400: 60
Ports
Inlet: 2″
Outlet: 1 1/2″
Berat: 60.0 kg
PERFORMANCE RANGE
- Flow rate up to 450 l/min (27 m³/ h)
- Head up to 112 m
APPLICATION LIMITS
- Manometric suction lift up to 7 m
- Liquid temperature between -10 ° C and +90 °C
- Ambient temperature between -10 ° C and+40 °C
- Max. working pressure 10 bar ( 6 bar for 2CP25/130N)
- Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
EN 60335-1 EN 60334-1
IEC 60335-1 IEC 60334-1
CEI 61-150 CEI 2-3
CERTIFICATIONS
Company with management system certified DNV ISO 9001 : QUALITY
ISO 14001: ENVIRONMENT
INSTALLATION AND USE
Suitable for use with clean water and with liquids that are not chemically aggressive towards the materials from which the pump is made. The high performance and adaptability to a wide range of applications make them the ideal choice in domestic, civil and industrial applications, in particular for the distribution of water in combination with pressure tanks for boosting pressure in the network and firefighting sets.
The pump should be installed in an enclosed environment or sheltered from inclement weather.
OPTIONS AVAILABLE ON REQUEST
- Special mechanical seal
- Other voltages or 60 Hz frequency
- IPX5 class protection for:
– 2CP32/200 – 2CP40/180
– 2CP32/210 – 2CP40/200