Specification product:
Three Phase ( HF 30A)
Power:
KW: 7.5
HP: 10
Flow Rate (Q) = m3/h : Total manometric head = metres
0: 23
12: –
18: –
24: –
30: –
36: 23
42: 23
48: 23
54: 23
60: 23
66: 22.5
72: 22.5
84: 22.5
96: 22
102: 21.5
108: 21
120: 19.5
132: 18
Flow Rate (Q) = l/min : Total manometric head = metres
0: 23
200: –
300: –
400: –
500: –
600: 23
700: 23
800: 23
900: 23
1000: 23
1100: 22.5
1200: 22.5
1400: 22.5
1600: 22
1700: 21.5
1800: 21
2000: 19.5
2200: 18
Ports
Inlet: 4″
Outlet: 4″
Berat: 65.2 kg
PERFORMANCE RANGE
- Flow rate up to 2200 l/min (132 m³/ h)
- Head up to 24.5 m
APPLICATION LIMITS
- Manometric suction lift up to 7 m
- Liquid temperature between -10 ° C and +90 °C
- Ambient temperature up to +40 °C
- Max. working pressure:
– 6 bar for HF 4
– 10 bar for HF 6-8-20-30
- Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
EN 60335-1 EN 60334-1
IEC 60335-1 IEC 60334-1
CEI 61-150 CEI 2-3
EU REGULATION N. 547/2012
CERTIFICATIONS
Company with management system certified DNV ISO 9001 : QUALITY
ISO 14001: ENVIRONMENT
INSTALLATION AND USE
Suitable for use in civil and agricultural applications. The high efficiency and continuous duty capabilities makes these pumps ideal for use in activities such us flood and spray irrigation, drawing water from lakes, rivers and wells, or for any number of different industrial applications where the characterictics of high flow rates and mind to low head are required.
The pump should be installed in an enclosed environment or sheltered from inclement weather.
OPTIONS AVAILABLE ON REQUEST
- Special mechanical seal
- Other voltages or 60 Hz frequency