The Satam “Master Meter” product range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard that can be used regularly to check and calibrate measuring instruments or measuring systems. With minimal dimensions, it can easily be moved to several different sites without the requirement for lifting tools.
Equipped with an Equalis electronic register that ensures linearization of measurements, it can be used with liquids of various viscosities without loss of accuracy.
Sector of application
Oil depots
For oil product reception and loading stations for tank truck, tank car and ships.
Hydrocarbon transportation
Distribution of fuel oil or fuel by road tanker.
Aircraft refuelling
Aircraft dispensers and aircraft fuelling tankers.
Army
Depot supplies and loading of trucks.
Transport companies
Refuelling of locomotives, trucks and public transport coaches.
Marine applications
Refuelling of ships.
Mining sites
Refuelling of trucks or site machinery.
Design of the master meter
Robust construction
Positive displacement meter with moving blades.
Modular design
Available with mechanical or electronic register.
Calibration for different viscosities
Supplied with one calibration certificate per each operating viscosity
Key points
Compact design
Calibration device of reduced weight and dimensions.
Possibility to move the ZCM 17 to different sites without the requirement for lifting tools
Self powered technology
Functioning of the mechanical register version without any power supply.
Modular design
Wide range of accessories to create your customized calibration device.
Can be installed on a trolley as mobile calibration equipment.
Stability and accuracy of measurements
Stable and accurate volume measurement without any influence of installation position.
Flowmeter manifold separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement accuracy.
Technical data – Master meter ZCM17 48
Application : Master meter dedicated to calibration of custody transfer volume measuring equipments
Max. Operating flowrate m3/h – L/mn – USGPM : 48 – 800 – 210
Min. Operating flowrate m3/h – L/mn – USGPM : 4.8 – 80 – 21
Measured parameters : Operating volume Base volume (only for ZCM 17 IE)
Measured liquids : Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester oils
Connections : Flanges or dry couplings*2 x 3 m hoses*
Meter:
Diameter : 2″
PD meter : ZC17-48
Versions ZCM 17 IM
Register : Mechanical register (VR). Total volume with reset: 5 digits. Total volume without reset: 8 digits
Volume display : Operating volume
Flowrate display : Included with IDI module L/mn or m3/h
Calibration curve : 7 flowrate values with 2 values per flowrate. One curve per operating viscosity
Calculation of reference volume : Manual calculation
Temperature measurement* : Local display
Pressure measurement* : Local display
Drainage equipment* : Manual drainage pump with purge valve and 2 release valves
Trolley* : Calibration device mounted on chassis with 4 pivoting wheels
Operating conditions :
Pressure : 10 bar max
Viscosity : 50 cSt max.
Liquid temperature : -10 °C to +80 °C
Ambient temperature : Standard : – 25 °C to + 55 °C – Option : – 40 °C to + 55 °C
Metrological performances :
Volume accuracy : < ± 0,1%
Volume repeatability : <± 0,02%
Temperature accuracy : <± 0.5°C
Versions ZCM 17 IE
Register : Electronic register (Equalis). Total volume: 6 digits Secure storage of ZCM 17 calibration curves. Calculation of reference volume
Volume display : Operating volume, base volume
Flowrate display : Included
Calibration curve : 7 flowrate values with 2 values per flowrate. One curve per operating viscosity
Calculation of reference volume : Automatic calculation
Temperature measurement* : Pt 100
Pressure measurement* : Local display
Drainage equipment* : Manual drainage pump with purge valve and 2 release valves
Trolley* : Calibration device mounted on chassis with 4 pivoting wheels
Operating conditions :
Pressure : 10 bar max
Viscosity : 50 cSt max.
Liquid temperature : -10 °C to +80 °C
Ambient temperature : Standard : – 25 °C to + 55 °C – Option : – 40 °C to + 55 °C
Metrological performances :
Volume accuracy : < ± 0,05% with linearization
Volume repeatability : <± 0,02%
Temperature accuracy : <± 0.5°C