THERMOMETER LUTRON TM-2000


Detail LUTRON THERMOMETER TM-2000

Features :

  • 3 in 1, Infrared thermometer + Pt 100 ohm thermometer + thermocouple ( Type K, J, R, E, T,) thermometer.
  • The best proffesional thermometer in the world
  • Microcomputer circuit with high performance
  • Wide temperature measuring range
  • Build in C & F select button on the front panel
  • 0.1 degree resolution for Pt 100ohm and type K/J/T/E
  • Data hold function for storing the desired  value on display
  • Memory function to record the maximum and minimum reading
  • Build in REL button, useful for relative measurement
  • LCD display with back light
  • Sensor select button on the front panel, easy to change different type probe
  • Infrared thermometer, non-contact temperature measurement, 0-20C  to 400C  *(-4F  to 752F), precise non contact temperature measurement
  • Amissivity adjustment for IR thermometer
  • Laser guide for IR temperature measurement
  • 4 wires PT 100 probe input, cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751, high precision
  • Thermocouple probe accept 5 different types : K,J,R,E,T
  • RS-232, Dara output easily cooperate with computer
  • Optional data acquisition software for data record
  • Auto power off saves battery life
  • Built-in low battery indicator
  • Heavy duty and compact housing case with stand

GENERAL SPECIFICATIONS

  • Display : 51×32 mm super large LCD display, 15 mm ( 0.6 inch ) digit size
  • Sensor type :
    1. Infrared thermometer ( No contact temperature measurement )
    2. Platinum Pt 100 ohm ( 0.00385 alpha coeficient, meet DIN IEC 751 )
    3. Thermocouple probe
    @ Thermocouple type K
    @ Thermocouple type J
    @ Thermocouple type T
    @ Thermocouple type E
    @ Thermocouple type R
  • Functions : ℃ ℉, Data hold, Memory ( Max. Min ), Relative measurement, Emissivity adjustment ( IR thermometer )
  • Resolution : 1 degree or 0.1 degree
  • Circuit : Exclusive microcomputer circuit, the software build in linearity correction instead the traditional hardware circuit
  • Emissivity adjustment : Range : 0.20 to 1.00
    Adjustment by pushing button on front panel
  • Laser quide : Red laser light, less tahn 1 mW, Meet EN60825
  • Probe input socket :
    Pt 100 ohm probe : DIN 4 pin socket
    Thermocouple couple probe : Standard 2 pin thermocouple socket
  • Sampling time : Approx. 1 second
  • Hold function : To freeze the display reading value
  • Memory recall : Memorize the maximum, minimum reading with recall
  • Offset adjustment : Available for IR thermometer, Pt 100 ohm and thermocouple thermometer adjustment by pushing button on front panel
  • Over indications : Show “—“
  • Data output : RS232 PC serial interface
  • Power supply : Alkaline or heavy duty type, DC 9V battery, 006P, MN1604 ( PP3 ) or equivalent
  • Power consumption :
    Approx. DC 11 mA ( Laser guide off )
    Approx. DC 16 mA ( Laser light on )
    * Above consumption value is calculated under the function of IR thermometer and without LCD back light
  • Operating temp : 0 to 50 C (32 to 122 F )
  • Operating humidity : Less than 80% R.H
  • Dimension : 200x68x30 mm